Fire Protection Services London

Residential sprinklers, water mist, fire curtains, alarms and maintenance — specified and installed by a directly appointed M&E contractor.

Get Free Fire Safety Survey
Direct Price / Grant Anchor £1,500–£2,500 / Dwelling
Procurement Advantage 0% JCT Markup (-15%+)
Stage Payment Terms 10 / 60 / 30 · £0 Retention
Compliance Standard BS 9251:2021 · BS EN 14972-17

Our certification status — stated honestly

We are not yet a BAFE, FIRAS or LPCB certified installer, and we do not claim to be. What we hold and what is in progress is listed below and kept up to date.

  • Held: CPVC fire-sprinkler pipe installer training (BlazeMaster, 2016 — renewal in progress)
  • In progress: manufacturer installer authorisation for water mist and fire/smoke curtains
  • Planned for 2027 (not yet applied): independent third-party installer certification — IFC SDI-22 (residential sprinklers) and SDI-25 (water mist); SDI-05 (curtains) as a later scope extension
  • Not held: BAFE, FIRAS, LPCB accreditation

See the full certification register and how to verify each claim →

How a project runs — survey, design, install, handover

One sequence on every fire job, whether it is a single loft conversion or a block of flats. You always see the design and a fixed price before any materials are ordered.

1

Survey and flow test

We attend site, record the cold-water flow and pressure, check the electrical supply route and access, and confirm the fire strategy with your architect or fire engineer. For mist this is the pre-installation check: minimum 6 litres/min at 1–10 bar at the pump connection.

  • Free initial survey
  • Flow and pressure recorded
  • Access and containment reviewed
2

Design and fixed quotation

The system is designed to the manufacturer's DIOM and the relevant standard (BS 9251 for sprinklers, BS 8458 / BS EN 14972-17 for mist, BS 8524 for curtains). You receive drawings, the hydraulic basis and a fixed price for the defined scope — before anything is ordered.

  • Manufacturer-compliant design
  • Drawings and scope schedule
  • Fixed price, no day-rate surprises
3

Installation

First fix is typically half a day for a dwelling: pump position, the ¾" washing-machine isolation valve connection, a 13 A fused spur within 1 m on FP200 cable with a Type C breaker and no shared RCD. Second fix and heads follow once ceilings and decorations are ready.

  • One cold supply per pump
  • CPVC or manufacturer pipework
  • Occupied properties planned around access
4

Commissioning and handover

We pressure-test, commission to the manufacturer's form and hand over the certificate, as-installed drawings and O&M information. Maintenance is offered at handover so the system stays certified for its design life.

  • Hydrostatic / flow test
  • Commissioning certificate
  • O&M pack and maintenance offer

Payment follows the direct-appointment model: 10% on design, 60% before materials, 30% on completion — no JCT and no retention. Where an installer certification or manufacturer authorisation is still in progress, the work is specified and installed under the manufacturer's certified system and installer network; our certification register shows the current status of every credential.

Our Fire Protection Services

🚿

Sprinkler Systems

Residential systems to BS 9251; commercial and industrial systems to BS EN 12845 and LPC Rules. Design, installation, commissioning and maintenance.

  • Wet sprinkler systems
  • Dry sprinkler systems
  • Residential & commercial
  • Annual servicing

New-build from £1,000/apartment · conversion £7,800–12,500

💨

Water Mist Systems

Mains-fed water mist to BS 8458 / BS EN 14972-17 — ideal for loft conversions, open-plan floors and spaces with limited water supply.

  • High-pressure mist systems
  • Low-pressure mist systems
  • Minimal water damage
  • BS 8458 / BS EN 14972-17

Indicative £1,500–2,500 per dwelling (survey required)

🔔

Fire Alarms

Design and installation of fire detection and alarm systems to BS 5839-1 for all building types.

  • Category L1, L3, L5 systems
  • Addressable panels
  • Conventional systems
  • 24/7 monitoring options

From £1,200 domestic

🪜

Dry & Wet Risers

Installation and testing of dry and wet riser systems for fire brigade use to BS 9990.

  • Dry riser installation
  • Wet riser installation
  • Annual pressure testing
  • Flow testing

From £3,500 installation

🧯

Gas Suppression

Clean agent fire suppression systems for server rooms, archives and critical infrastructure.

  • FM-200 systems
  • NOVEC 1230 systems
  • Design & installation
  • Annual maintenance

From £18,000

📋

Fire Safety Surveys

Comprehensive fire safety assessments and compliance audits for your property.

  • Fire risk assessments
  • Compliance audits
  • System inspections
  • Recommendations report

Free initial survey

Standards & Compliance

All our fire protection work is carried out to the highest standards and current regulations.

BS EN 12845

Fixed firefighting systems - Automatic sprinkler systems

LPC Rules

Loss Prevention Council Rules for automatic sprinkler installations

BS 5839-1

Fire detection and fire alarm systems for buildings

BS 9990

Non-automatic firefighting systems in buildings

BS EN 14972-17:2025

Water mist systems — test standard (BS 8458 / BS 8489 are withdrawn)

BS 9251

Residential and domestic sprinkler systems

BS 8524

Active fire curtain assemblies

Regulatory Reform (Fire Safety) Order 2005

England and Wales fire safety legislation

Certification we are working towards

Listed here as our target schemes, not as held accreditation. We will publish each certificate number on the day it is issued — see certifications for verification links.

Residential & domestic sprinkler systems — planned 2027 (not yet applied)

Water mist systems — planned 2027

Fire & smoke curtains — planned 2027

Indicative Pricing Guide

Service Indicative price Notes
Water mist retrofit (per dwelling) £1,500–2,500 Automist-type system, typical 1–2 bed flat; survey required
Residential sprinklers — new-build / batch from £1,000 / apartment Minimum 10 units per site; design and commissioning included
Residential sprinklers — single conversion £7,800–12,500 / unit Occupied dwellings to BS 9251; access and fire-stopping dependent
Residential sprinklers — block retrofit £2,600–4,700 / apartment Occupied blocks; access, fire-stopping and out-of-hours drive the variance
Fire & smoke curtains from £3,800 / opening Small ≤2 m from £3,800 · medium 2–4 m £6,000–10,800 · large/atrium £9,800–21,500 — controls included
Maintenance — portfolio / per unit £150–280 / unit / yr Annual service and certification; unit-rate on portfolios
Curtain annual drop test (per opening) £180–320 / opening / yr Annual drop test and record — confirm band at survey
Maintenance — standalone home £250–450 / yr Single-dwelling annual visit; travel and mobilisation included
Fire alarms, dry/wet risers, gas suppression Quoted on survey BS 5839 / BS 9990 systems — priced per project

* All prices are indicative planning ranges and subject to site survey, system design and current manufacturer pricing. Contact us for a detailed fixed quotation. Pricing is per dwelling/apartment/opening as stated — turnkey supply-and-install; enabling works (making good, electrical supply upgrades beyond the 13 A spur, tank/pump where required) are priced separately after survey.

Interactive Fire Suppression Estimator

Calculate an indicative turnkey budget for your residential project with transparent 10/60/30 milestone stages.

1. Select System & Scope

Mains-fed: operates on just 6.0 l/min at 1.0–10.0 bar dynamic pressure without water storage tanks.

Direct-mains compatible. Plumis Automist requires no storage break tank or Thames Water Section 45 highway upgrade.

2. Turnkey Investment Estimate

Estimated Net Total: £2,000
VAT (20% standard rate): £400
Total Estimated (inc VAT): £2,400

Direct Appointment Payment Stages (10 / 60 / 30)

10% Deposit: Survey, CAD & Hydraulic Calculation £200
60% First Fix: Plant Delivery & Concealed First-Fix £1,200
30% Commissioning: 2h Hydrostatic Test & Handover £600
Governing Standard: BS EN 14972-17:2025 (water mist) · Manufacturer-certified system — installer certification is not held by M&E Solutions

* Indicative planning estimate for standard residential layouts. Subject to on-site hydraulic flow test, geometric survey and structural access.

Fire suppression — questions we are asked most

Do I need sprinklers or mist for a loft conversion?

It depends on the fire strategy for the building, not on a single rule. Many loft conversions and open-plan ground floors are resolved with a water-mist system, because it avoids enclosing every corridor or upgrading all doors — but the decision belongs to the fire strategy and Building Control. We survey, design to the manufacturer's DIOM and the relevant standard, and coordinate with your architect or fire engineer.

Does water mist need a tank or a booster pump?

No. A mains-fed mist system takes one cold supply per pump at a minimum 6 litres/min at 1–10 bar, terminating in a standard ¾" washing-machine isolation valve. That is the reason it suits loft conversions and HMOs where a sprinkler tank would take the floor area you are trying to create.

How much disruption is an installation?

First fix (a 13 A fused spur within 1 m of the water supply, on FP200 cable, plus the water connection and backboxes) is typically half a day; second fix and commissioning is typically one day. Occupied properties are planned around access and working hours.

What certification do you hold?

We state it plainly: CPVC fire-sprinkler pipe installer training (2016, renewal in progress); manufacturer installer authorisation in progress; independent third-party certification (IFC SDI-22 residential sprinklers, SDI-25 water mist) planned for 2027 and not yet applied for. We do not hold — and do not claim — BAFE, FIRAS or LPCB accreditation. The live register is on our certifications page.

How much does it cost?

Indicative: mist retrofit £1,500–2,500 per dwelling; residential sprinklers from £1,000 per apartment on new-build batches, £7,800–12,500 for a single conversion; curtains from £3,800 per opening; maintenance £250–450/yr for a single dwelling. Every quote follows a survey and design — see the pricing guide above.

Do you maintain systems you did not install?

We can service systems where the design and component records are available. We will tell you up front if a system cannot be maintained to the standard, rather than issuing a certificate that hides a problem.

How long does a project take from survey to handover?

A typical single dwelling is one survey visit, a design and fixed-price stage, one half-day first fix and one day of second fix and commissioning; the certificate and O&M pack follow at handover. Block, care-home and curtain projects are programmed per building around access, other trades and the fire strategy — we agree the programme before ordering.

Can you install in an occupied home or a rented flat?

Yes — most of our residential work is in occupied properties. Because a mains-fed mist system needs no tank, work is planned around working hours, access, protection of floors and furniture, and making good. For rented flats we agree access and any landlord or managing-agent requirements before booking, and we work to the tenancy arrangements you have.

What if my cold mains flow is below 6 litres/min?

We record static and dynamic flow during the survey. If the supply cannot support mains-fed mist, the options are an in-line accumulator or a sprinkler break tank with a Category 5 Type AB air gap, or a BS 9251 sprinkler design. We quote the option that fits the building rather than forcing the lowest-cost system onto a low-flow supply.

Who approves the design — do I still need Building Control?

The fire strategy and Building Control approval stay with your architect or principal designer. We provide the system design, hydraulic calculation, manufacturer data and commissioning certificate for that submission, and we coordinate the interfaces with the other trades so the installed system matches the approved strategy.

Get Your Free Fire Safety Survey

Contact us today for a comprehensive fire safety assessment of your property.